Filter Results By:

Products

Applications

Manufacturers

Showing results: 1576 - 1590 of 2605 items found.

  • 256 Channel Power Supply

    IDPS750 - Salland Engineering

    Salland Engineering’s Independent Device Power Supply (IDPS) can expand your existing Automated Test Equipment (ATE) with up to 256 independent DPS sources to increase parallel testing. It offers Force Voltage (FV) and Measure Current (MI) that can be used for continuity tests, parametric supply current (IDD) and quiescent supply current (IDDQ) measurements or simply for powering devices under test. The IDPS750 is targeted to reduce test costs for a wide range of applications including smart cards, memory, microprocessors and FPGA’s. Its design makes it useful in applications where many resources are required, or were the original ATE supplies do not meet your required specifications.

  • LED Test Programmable DC Electronic Load

    IT8912E Series - I-TECH Electronic Co., Ltd

    IT8900 series high accuracy LED specific testing electronic loads can simulate the real output of LED lights with different characteristics.Their specific circuit can realize CR-LED mode, adjustable frequency, duty ratio PWM dimming output port (frequency: 20Hz-2KHz), I-pp/I-max measurement function can test current ripple and start up surge current of LED constant flow source. Voltage and current testing speed can reach 50KHz. IT8900 series provides CR-LED / CC / CV + CC / CR /CW and other working modes, built-in USB / RS232 / GPIB communication interface. Widely used in LED driver power dimming test.

  • Integrated Function Tester for Inductance Ballast

    UI2001B - Lisun Electronics Inc.

    • Measure input parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components. V range: 10.0~300.0V, A range: 0.010~2.000A, F range: 45~65Hz • Measure output parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components Lamp voltage range: 10.0~450.0V, Lamp current range: 0.010~2.000A • Accuracy: ± (0.4% reading+0.1% range+1 digit) • Can test every kind of curve, print both data & curve • Communication interface available for PC, running under Windows98/2000/XP/Vista

  • HDCD Battery Charge Tester

    HD Power Test Equipment Co.ltd

    HDCD Battery Charge Tester is mainly used for the charge test of the lead-acid battery of the backup power supply in the telecommunications, mobile, substation, railway transportation and pertrochemical industry power DC industries. It keeps the constant communication maintain between the battery charge ensuring a perfect charge.Battery charge tester is designed using intelligent three-stage charging mode to achieve the function of automatic conservation between charging and floating charge. It also can on-line detect the voltage of the whole battery, real-time display and record the voltage of whole battery. The tester can automatically accomplish charging after setting the parameter of voltage, current, time and capacity.

  • PXIe High-Speed Source/Measure Unit, 13 V, ± 1 A or 6 V, ± 3 A, 18 W

    M9111A - Keysight Technologies

    The M9111A is a 1-slot, 2-quadrant PXIe module that provides stable, glitch-free sourcing and sinking, and high accuracy measurements. It offers high-throughput and measurement quality for design validation and production test of RF power amplifiers. With industry-leading output stability under extreme, dynamic load conditions and unmatched transient performance to dramatically reduce voltage droop due to pulse loading, the M9111A SMU speeds test time. The high-speed M9111A can change its output voltage, stabilize that voltage, and accurately measure current from Amps down to micro-Amps all in less than 1 ms so that you can move on to the next test as quickly as possible.

  • Multifunction Electrical Installations Meter

    MPI-525 - Sonel S.A.

    Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.

  • ELECTRICAL LOAD BOX

    Temis S.r.l.

    The Electrical Load Box LOADS in charge to simulate the typical consumption of electronics’ equipment.The Box is a 5U, 19’’ modular rackable equipment that can house up to 50 resistors mechanically and thermally attached to two high efficiency heat-sinks, with integrated fans, for each boxTesting points for current and voltage measurement are provided as well

  • Electrolytic Capacitor Analyzer

    13100 - Chroma ATE Inc.

    Analyzer is a general measurement instrument designed for analyzing the features of electrolytic capacitor s. It has multiple func tions that can be programmed based on the capacitor features by altering the settings to test metal oxidization thin-film withstand voltage, capacitor leakage current, capacitance, dissipation factor, impedance and equivalent serial resistance, etc.

  • High-Voltage Power Amplifier

    Model 609B-3 - TREK, INC.

    The Trek Model 609B-3 is a DC-stable, high-voltage power amplifier designed to provide precise control of output voltages in the range of 0 to ±10 kV DC or peak AC with an output current range of 0 to ±2 mA DC or peak AC. The 609B-3 can be configured as a noninverting amplifier, as an inverting amplifier, or as a differential amplifier.

  • Operational Amplifier

    Op Amp Series - Texas Instruments

    The amplifier is capable of operating at supply voltages from 0.9V to 3V with specified specs at 1V and 1.8V single supply.The input common mode range extends to both power supply rails without the offset glitch and input bias current phase reversal inherent to most rail to rail input amplifiers.

  • PCI Express 8 Reed Relay Output

    8012eS - Sealevel Systems, Inc.

    The 8012eS PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.

  • Single Channel Potentiostats

    Apps-XM Series - Ametek Scientific Instruments

    This family of instruments is built on the technology of the ModuLab XM platform. Specific combinations of options, such as frequency response analyzers (FRA), current boosters, voltage boosters, are popular when the ModuLab XM is configured for given applications. We combine our design knowledge and industry experience to create a line of products with an application focus.

  • Single Phase Lock-In Amplifier

    SR510 - Stanford Research Systems, Inc.

     The SR510 and SR530 are analog lock-in amplifiers which can measure AC signals as small as nanovolts in the presence of much larger noise levels. Both the single phase SR510 and the dual phase SR530 have low-noise voltage and current inputs, high dynamic reserve, two stages of time constants, and an internal oscillator. 

  • 16 Channel 16 Bit VME Analog Output Card

    PAS 9816/AO - Precision Analog Systems Co.

    The PAS 9816/AO provides sixteen analog output channels with sixteen bit resolution on a standard 6U x 160mm VME card. Analog output voltage range is ± 10 Volts with ± 5 mAmp output current drive per channel. Settling time is 3 uSec typically and 4 uSec maximum.

  • Arc Resistance

    National Technical Systems

    The intent of arc resistance testing is to distinguish between solid electrical insulating materials. It examines the specimen’s ability to resist an arc with high voltage and low current exposed to the material’s insulating surface. The ASTM arc resistance test for dry and uncontaminated materials centers on the time elapsed until tracking paths form.